1. <sub id="oycqq"></sub>
      <nav id="oycqq"></nav>
          1. G210A

            G210A.jpg


            FEATURES:

            Support small-capacity battery and capacitor research test, 0~5V full range controllable.

            Supports precision research and testing with 0.01% voltage and current accuracy.

            Support high-rate fast charge research, 30C can achieve 0.01% capacity accuracy; 100C can reach 0.1% capacity accuracy.

            Support custom pulse test with a minimum pulse width of 50mS.

            Full coverage of the measurement records of the voltage, current, capacity, energy, efficiency, capacitance, internal resistance and other parameters required for the study.

            The device comes with UPS and storage to effectively prevent data loss and damage caused by downtime, sudden power failure, network failure, etc.


            G210A PERFORMANCE:

            ITEM

            INSTRUMENT PERFORMANCE

            Range

            Voltage

            5V (DC to -5V)

            Current

            10A

            No.of CHANNELs


            8Chl

            ACCURACY

            (SET,READ)

            Voltage

            ±0.01%RD±0.01%FS

            Current

            ±0.01%RD±0.01%FS

            TIME

            ≤±5uS/S (Equipment autonomous control, no communication and other time delay errors)

            INPUT IMPEDENCE


            10GΩ

            DATA RECORD

            Sampling Rate

            100Hz(Sampling interval 10mS

            Setting Method

            Interval time, Sampling rate

            PROCESS CONTROL

            Work Mode

            REST/ CC / CV / CRATE

            DC / DRATE

            End Conditions

            IME / VOLTAGE / CURRENT / POWER / CAPACITY / ENERGY

            PHASE CYCLE

            Protective Function

            Power-off data protection, Net break protection

            User-defined safety: Over voltage, Under voltage, Over current, Over rate, Over capacity.

            FUNTION


            DCIR、Capacitance capacity calculation、Step pluse、Three-electrode testReference test)、DQ/DV

            OUTPUT


            Four electrodes (support reference electrode test)

            COMMUNICATION


            10/100M Ethernet(RJ45)、RS232(Console)

            OPERATING ENVIRONMENT

            Temperature

            0~40℃(23±2Optimum accuracy

            Humidity

            90% No condensation

            EQUIPMENT SIZE


            3U  W*H*L:430*420*135(mm)

            POWER SUPPLY


            AC220V~±10% 50Hz / AC110V~±10% 60Hz, 260W

            Note: For best test accuracy and safety, be sure to ground well. The machine needs to be warmed for 30 minutes before use.